MS-9200UDLS MS-9200UDLSE MS-9200UDLSC - Fire. 11 Images about MS-9200UDLS MS-9200UDLSE MS-9200UDLSC - Fire : Free download Ms 9200 Fire Lite Manual programs - backuperlawyer, Fire Lite Miniscan Manual - gettsnow and also Panel de incendio direccionable de 01 lazo MS-9200UDLS - Fire Lite. Honeywell MS-9200UDLS, MS-9200UDLSE manual Programming, Installation, Product Description, Operating Instructions, Power Supply Calculations, Remote Site Upload/Download, SECTION 5 Central Station Communications, WEEK, MASTER, MS-9200UDLS. MS-9200UDLSE. IMPORTANT! User Manual: Locks Fire Lite MS9200UDLS User Manual Security Product Manuals - Northeast Security SolutionsNortheast Security Solutions . 12 MS-9200UDLS PN 52750:E1 01/27/09. PS2 Keyboard I nterface DACT Pho ne Line Jacks (Non power-L imit ed) Rese tt able Powe r - 24 VDC filte red, power-l imite d 134 MS-9200UDLS Series Manual —P/N 52750:M 11/20/2015 Normal Operation Operating Instructions Supervisory This is a yellow LED that flashes when one or more supervisory conditions occur, such as a sprinkler valve tamper condition. It illuminates steady when the Acknowledge/Step or Alarm Silence key is pressed. MS-9200UDLS(E) Intelligent Addressable FACP with Built-In Communicator Addressable DF-52422:B † A1-40 52422cov General The Fire†Lite MS-9200UDLS is a combination FACP (Fire BG-12LX: Addressable manual pull station with interface mod-ule mounted inside. I300: Fault Isolator Module. This module isolates the SLC Technical Manual 12 Clintonville Road, Northford, CT 06472 ® MS-9200 Addressable Fire Control Panel (Export Version) P/N 50428:B1 ECN 97-316 DOCUMENT # 50428 7/28/97 REV: B. WARNING: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may NOTE: Unless otherwise specified, the term MS-9200UDLS is used in this document to refer to both the MS-9200UDLS and the MS-9200UDLS(E) FACPs (Fire Alarm Control Panels). Features † Listed to UL standard 864, 9th edition. † On-board DACT. † Remote site or local USB port upload/download, using PS-Tools. This document describes the operation, installation and wiring of various Signaling Line Circuit (SLC) devices when used with the Fire-Lite MS-9200/MS-9200E, MS-9600/MS-9600E, MS- 9600LS/MS-9600LSC/MS-9600LSE, MS-9600UDLS/MS-9600UDLSE, MS-9200UD/MS- 9200UDE, MS-9200UDLS/MS-9200UDLSE/MS-9200UDLSC, and MS-9050UD/MS- 9050UDC/MS-9050UDE control panels. 1211 S. Main Street Angels Camp, CA 95222 US 1-800-983-5300 admin@signalserviceinc.net MS-9200UDLS Series Manual Multiple Download been Selected MS-9200UDLS Installation Document Multiple Download been Selected ZNAC-92 Class A Converter Module Multiple Download been Selected 9200 UDLS Version 6 Multiple Download been Selected Manual 53688 Multiple Download been Selected MS-25 Battery Calculation Multiple Download been Selected FireLite SLC Wiring Manual — P/N 51309:R2 3/19/2019 3 Installation Precautions Adherence to the following will aid in problem-free installation with long-term reliability: WARNING - Several different sources of power can be connected to the fire alarm control panel. Disconnect all sources of power before servicing. Control unit and associated MS-9200UDLS: 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed circuit board mounted on chassis, and cabinet. 120 VAC operation. - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE S
© 2024 Created by Andres Gonzalez. Powered by
You need to be a member of RhinoFabStudio to add comments!
Join RhinoFabStudio