RhinoFabStudio

Parametric Design + Optimization + Digital Fabrication

Hp vc flex-10 enet module manual

 

 

HP VC FLEX-10 ENET MODULE MANUAL >> DOWNLOAD LINK

 


HP VC FLEX-10 ENET MODULE MANUAL >> READ ONLINE

 

 

 

 

 

 

 

 











 

 

The HP Flex-10 10Gb 2-port 552M is a Flex-10 10 Gigabit Ethernet (10GbE) mezzanine card for BL-c Gen8 servers that utilizes the Emulex BE3 controller. The HP 552M adapter supports Virtual Connect Flex-10, which allows each 10Gb port to be divided into four physical NICs to optimize bandwidth management for virtualized servers. 1. HP BladeSystem c7000 enclosure, single phase 1. HP Virtual Connect Flex-10 10-Gb Ethernet modules (redundant pair) 2. HP ProLiant BL460c G6 (half-height) server blade (recommended configuration for central management server, hosting the management software, but can be substituted) 2. HP Virtual Connect 8Gb 24-Port FC modules (redundant pair) The HPE BladeSystem c-Class Virtual Connect Support Utility enables administrators to upgrade VC-Enet and VC-FC firmware, and to perform other maintenance tasks remotely on both BladeSystem c-Class c7000 and c3000 Enclosures using a standalone command line utility. In the below example I will perform firmware upgrade on my HP VC Flex-10/10D I also recently managed to find the manual page for the HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem on HP's site which is a good reference launch page for the latest HP Virtual Connect Ethernet Cookbook and all other Flex-10 related documentation. Cooking with Flex-10. HP's Virtual Connect Ethernet HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem - 8 x XFP 276 Upgrading to an HP Virtual Connect 8Gb 20-PortFC Module. 277 For detailed migration information, see the; VC-managed; identifiers; 2.Delete the domain; 3.Remove all network uplinks from the modules to be removed; 4.Remove the existing modules from both horizontally adjacent bays; 5.Install the HP Virtual Connect Flex-10,FlexFabric, or Flex HP Virtual Connect for Cisco Network Administrators (version 1.2x) page 5 console. VC Uplink Visible ports on the VC-Enet module faceplate that provide external connectivity for the enclosure. VLAN Trunk A single physical port or a single port channel with VLAN tagging enabled. VCは、サーバーエンクロージャーの管理をLANおよびSANの管理から明 確に分離します。 VCは、サーバー接続のセットアップおよび管理を簡略化し、次のコンポーネントを含みます。 • HPE Virtual Connect Manager • VC Ethernetモジュール: o HPE VC Flex-10 10Gb Ethernet A page with many whitepapers and manuals on how Virtual Connect works; Virtual Connect firmware can be done via HP SUM/ SPP. GB8007KF5D 1 HP VC Flex-10 Enet Module 3. 70 2012-07-03T20: 37: 31Z. GB8007KF5D 2 HP VC Flex-10 Enet Module 3. 70 2012-07-03T20: 37: 31Z . Total execution time: 00: 38: 48 . • HP VC Flex-10 10Gb Enet Module • HP VC FlexFabric-20/40 F8 Module • HP VC 4Gb Fibre Channel Module for BladeSystem c-Class (enhanced NPIV) • HP VC 8Gb 20-Port FC Module • HP VC 8Gb 24-Port FC Module IMPORTANT: Beginning with VC 3.70, the HP 1/10Gb VC Enet Module (399593-B22) and the HP 1/10Gb-F VC Enet Module (447047-B21) are no longer supported. After performing a manual reboot of one of the VC modules, it has booted up on the new firmware but is not synchronizing with the primary module Bay 1 : HP VC Flex-10 Enet Module. Power : On Health : Ok IP Address : xxx IP Connectivity : Passed Version : 4.41 Detailed information is displayed for supported VC modules only. 6. Enter the update command to update the firmware on supported VC-Enet and VC-FC modules in the enclosure. The update process takes approximately 20 minutes for VC-Enet modules, and 5 minutes for VC-FC modules to be updated. These updates are perfo

Comment

You need to be a member of RhinoFabStudio to add comments!

Join RhinoFabStudio

Translate Language:

RhinoFabStudio

Learn all about Rhino

© 2024   Created by Andres Gonzalez.   Powered by

Badges  |  Report an Issue  |  Terms of Service